74 | FIRE DETECTION SYSTEMS | AUTOMATIC OPENINGVENT SYSTEM t: 0845 884 7000 | f: 0845 884 6000 | w: www.channelsafety.co.uk | @channelsafety | EDITION 7 AOV Smoke Ventilation System WHAT IS AN AOV? AOV is simply an abbreviation for“Automatic Opening Vent”. An AOV system is a control system designed to vent air or smoke for use in natural & smoke ventilation. SO WHY DO I NEED AN AOV SYSTEM? AOV control systems are used mainly to control the ventilation of smoke in a fire. Changes to building regulations were made due to the results of investigations into smoke inhalation. When a detector or call point is triggered an AOV control system will open actuators, windows or vents to create ventilation. This clears smoke for people leaving the building and vents smoke out of the area that has been triggered. The provisional standard that is now available for reference is EN:12101. WHAT AOV PRODUCTS DO I NEED? We supply 2 systems for AOV control; AOV single zone or AOV multi zone. Each panel can be triggered by detectors or call points. This will then activate actuators to open or close. HOW DO I DECIDE WHICH AOV SYSTEM TO FIT? You first need to decide what items you need to control on your system. You should work out how many items will need to open separately & then class each one as a zone. See the following examples: Example 1 You have one roof vent or window which must open when the fire alarm is triggered... In this situation you have 1 zone. You need to first see how the roof vent or window operates. If it is manual opening then you will need to add an AOV actuator which can be triggered to open or close. If there is already a fire system in place there may be smoke detectors fitted. In this situation you can link an AOV single zone to your fire system which will trigger when smoke is detected in that area. The AOV actuator when triggered will open, when reset it will close. Yellow call points can be added for override or system test. (If there is no fire system in place a detector can be fitted to trigger the system.) Example 2 You have 4 floors, a window on each, and a vent for a shaft on the roof... This situation would leave you with 5 zones. Here you would use an AOV multi zone panel which will be able to open/close each zone independently. Under this condition it may be that the vent should open together with any zone that is triggered. (A roof vent will be on a smoke shaft or stairwell. Opening it together with a window will then create a chimney effect clearing smoke.) In this case you can set the AOV multi zone with zone 1 as a“master”. A simple solution that will then trigger zone 1 together with any of the zones 2 - 5. Again you would then need to add an actuator to each window/vent and either link to your existing fire system or add call points & smoke detectors to the AOV multi zone system to trigger. Ventilation The AOV product range specified on these pages can be used for natural ventilation or smoke ventilation. PRODUCT FEATURES (MULTI ZONE PANEL) • For larger systems that require more than 1 zone to trigger separately • Independent system or intergratable panel • Triggers via a fire panel or an independent loop • Open or close all zones with firemans call point • Master zone capable - 1 zone (shaft / staircase) to trigger together with any other zone(s) • 3 Base Units - up to 5 zone, 10 zone or 15 zone TYPICAL APPLICATIONS • Multiple occupancy building with several zones • Shaft or staircase operating with separate zones • Large single areas with multiple windows or vents PRODUCT FEATURES (SINGLE ZONE PANEL) • For use on 1 zone where all items trigger together • Independent system or interchangeable panel • Triggers via a fire panel or an integrated loop • Model options: 1.5A, 2.5A, 4A or 10A • Enclosure size - 400 x 300 x 110mm • Requires 2x B/12V/12AH/SLA Batteries TYPICAL APPLICATIONS • Small multiple occupancy building common areas • Single stairwells - top window or roof vent • End of corridor windows