AOV Mutli Zone Panel
Product Code: F/CH/AOV

co-Logo
Smoke CO 1 Year EEA
Detection  Detection Guarantee  Conformity

You will require an AOV multi zone panel if (for example) you have 4 floors, a window on each, and a vent for a shaft on the roof. This situation would leave you with 5 zones. Here you would use an AOV multi zone panel which will be able to open/close each zone independently. Under this condition it may be that the vent should open together with any zone that is triggered. (A roof vent will be on a smoke shaft or stairwell. Opening it together with a window will then create a chimney effect clearing smoke.) In this case you can set the AOV multi zone with zone 1 as a “master”. A simple solution that will then trigger zone 1 together with any of the zones 2 – 5. Again you would then need to add an actuator to each window/vent and either link to your existing fire system or add call points & smoke detectors to the AOV multi zone system to trigger.

Email this product to a friend
Like on Facebook
Share this product on Twitter
  • For larger systems that require more than 1 zone to trigger separately
  • Independent system or intergratable panel
  • Triggers via a fire panel or an independent loop
  • Open or close all zones with firemans call point
  • Master zone capable – 1 zone (shaft / staircase) to trigger together with any other zone(s)
  • 3 Base Units – up to 5 zone, 10 zone or 15 zone
  • F/CH/AOV5/A |  AOV multi zone (1-5 zones) base unit 5 amp 24v (Requires 1x F/CH/AOVZ-01 for each zone)
  • F/CH/AOV10/A |  AOV multi zone (1-5 zones) base unit 10 amp 24v (Requires 1x F/CH/AOVZ-01 for each zone)
  • F/CH/AOV10/B | AOV multi zone (6-10 zones) base unit 10 amp 24v (Requires 1x F/CH/AOVZ-01 for each zone)
  • F/CH/AOV20/B |  AOV multi zone (6-10 zones) base unit 20 amp 24v (Requires 1x F/CH/AOVZ-01 for each zone)
  • F/CH/AOVZ-01 | AOV Zone card for multi zone control panels. (1x F/CH/AOVZ-01 is required for each working zone)
(OUTPUT OPTIONS) AOV ACTUATORS

  • F/CH/ACT-301 | 24v DC 1.35 amp actuator – 300N – reach 100mm to 400mm adjustable (L-290 x W-83 x H-48mm) Requires bracket for fixing (see below)
  • F/CH/ACT-501 | 24v DC 2 amp actuator – 400N – reach 800mm fixed (L-575 x W-80 x H-50mm) Requires bracket for fi xing (see below)
  • F/CH/ACT-502 | 24v DC 2 amp actuator – 400N – reach 600mm fixed (L-650 x W-80 x H-50mm) Requires bracket for fi xing (see below)
  • F/CH/ACT-503 | 24v DC 2 amp actuator – 400N – reach 450mm fixed (L-765 x W-80 x H-50mm) Requires bracket for fi xing (see below)
  • F/CH/ACT-701 | 24v DC 1 amp actuator – 300N – reach 380mm fixed (L-473 x W-51 x H-40mm)
  • F/CH/ACT-702 | 24v DC 1 amp actuator – 300N – reach 600mm fixed (L-613 x W-51 x H-40mm)
  • F/CH/ACT-703 |24v DC 1 amp actuator – 300N – reach 800mm fixed (L-713 x W-51 x H-40mm)
    BRACKETS FOR AOV ACTUATORS
  • F/CH/BRK-301 | Standard mounting bracket suitable for use with F/CH/ACT-301
  • F/CH/BRK-303 | Small swivel mounting bracket suitable for use with F/CH/ACT-301
  • F/CH/BRK-304 | Large swivel mounting bracket suitable for use with F/CH/ACT-301
  • F/CH/BRK-502 | Standard swivel mounting bracket suitable for use with F/CH/ACT-501, F/CH/ACT-502 or F/CH/ACT-503

(INPUT OPTIONS) AOV CALL POINTS & DETECTORS

  • F/CH/FVE/BGU | Smoke vent yellow break glass unit (no resistor)
  • F/CHBG/S/KS | Smoke vent yellow keyswitch (2 positions) open – closed
  • F/CHBG/KS/SV | Smoke vent yellow keyswitch (3 positions) automatic – open – closed
  • F/CHSW/2/Y | Smoke vent yellow rocker switch (2 positions) open – closed
  • F/CHSW/3/Y | Smoke vent yellow rocker switch (3 positions) automatic – open – closed
  • F/CH/SLR-E3N | Smoke vent detector (non latching)
  • F/CH/YBO-R/GRN | Relay base (non latching)

BATTERIES

  • B/12V/7AH/SLA | 12 Volt 7Ah sealed lead acid battery (1 block) – Suitable for 1-5 amp PSUs
  • B/12V/12AH/SLA | 12 Volt 12Ah sealed lead acid battery (1 block) – Suitable for 10 amp PSUs