GST Fire Panel
Product Code: F/CH/GST/

4 Wire EN54 1.75 Kg Not Included
System  Approval Weight  Batteries

Making use of advanced GST protocol, these systems are compatible with complete range of sounders, call points, GST intelligent detectors, interfaces including intrinsically safe and gaseous extinguishing control.

Owing to the attributes such as semi flush-mounted, flexible configuration unique design for modern technology and easy operation, these fire panels are widely appreciated in the market.

Email this product to a friend
Like on Facebook
Share this product on Twitter
  • 2 to 16 zones can be detected, compatible with conventional detectors. Each of the 16 detection zones can be individually configured as maximum 15 conventional detectors. The total number of detectors in a zone shall not exceed 32
  • 4 sounder outputs, 1 alarm output and 1 fault output
  •  Test and disable functions
  • Day/night mode settable
  •  Programmable on manual call point connection, sound modes, sounder delay modes and output delay modes
  • Able to report short circuit and open circuit of detection zones, sounder outputs and alarm output
  • Three access levels settable via a key switch and an internal switch
  • Reserved repeater panel interface for fi re alarm indication of multiple zones
  • Providing external ports includes RESET, SILENCE, EVAC and forced Night Modes
PANELS

  • F/CH/GST102A | GST 2 zone control panel requires 2 x B/12V/2.3AH/SLA battery
  • F/CH/| GST104A | GST 4 zone control panel requires 2 x B/12V/2.3AH/SLA battery
  • F/CH/GST108A | GST 8 zone control panel requires 2 x B/12V/2.3AH/SLA battery
  • F/CH/GST116A |GST 16 zone control panel requires 2 x B/12V/2.3AH/SLA battery

RELAY BOARDS

  • F/CH/GST/RB102A | Relay board for GST102A, for zonal fault and fi re alarm signal output
  • F/CH/GST/RB104A | Relay board for GST104A, for zonal fault and fi re alarm signal output
  • F/CH/GST/RB108A | Relay board for GST108A, for zonal fault and fi re alarm signal output
  • F/CH/GST/RB116A |  Relay board for GST116A, for zonal fault and fire alarm signal output

BATTERIES

  • B/12V/2.3AH/SLA | 12 Volt 2.3Ah sealed lead acid battery (1 block)
DETECTORS

  • F/CH/GST/C-9102 | Optical detector complete with remote indicator output without base
  • F/CH/GST/C-9103 | Fixed & rate of rise heat detector complete with remote indicator output without base

VISUAL INDICATOR

  • F/CH/GST/C-9314P | Passive remote indicator

END OF LINE UNIT

  • F/CH/GST/P-9907 | Active EOL unit for C series devices
    BASES
  • F/CH/GST/DB-01D | Innovation standard detector base complete with diode for innovation detector using DP-9907 AEOL 
  • F/CH/GST/DZ-03D | Detector base complete with diode when using P-9907 AEOL

REFLECTIVE BEAM DETECTOR

  • F/CH/GST/I-9105R | Reflective beam detector c/w 4 reflectors, 8-100 m, 24v DC